A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
Dimensions
Panel Cutout
IMPORTANT
Please read these instructions carefully to assure
correct installation. This equipment must be
installed by a licensed electrician. Prior to being
put into operation, check all wiring and function of
the unit.
TFH Installation Information
Specifications
Sensor Type: 100K Thermistor (Dual) - Length (15 ft.)
Other lengths available upon request.
Accuracy: +/-3ºF of Setpoint
Power Input: 24 VAC, 120 VAC
Control Operation: Low Limit - Closes on Rise
High Limit - Opens on Rise
Output Ratings:
Low Limit - 8 Amp S.P.D.T. Relay Max. @ 240 VAC Max.
High Limit - 8 Amp S.P.S.T. Relay Max. @ 240 VAC Max.
(Resistive Load)
Adjustable Time Delay Range: 18.5 Minutes
Adjustable Temperature Range: Low Limit: 30ºF to 65ºF
High Limit: 100ºF to 220ºF
Ambient Operating Temperature: -30ºF to 140ºF
(-35ºF to 60ºC)
Connections: 1/4” Quick Connects,
6” Wire Leads (Optional)
Package: Aluminum “C” Bracket - 5.1”L x 5.9”W x 3.1”D
(shown) Full Enclosure w/conduit knockout (optional)
Shipping Weight: 2 lbs. (.9 kg)
Connections
Thermistor Input: T1, T2 & T3 (100K ohm @ 25°C)
Power Input: T4 & T5 (24-120 VAC)
Low Limit Relay: T8 (N.O.), T9 (COM) & T10 (N.C.)
High Limit Relay: T6 (N.O.), T7 (COM)
Installation Note: For optimum accuracy, the sensor
must be mounted with a minimum of two feet of cable at
the sensor lug end being exposed to the same tempera-
ture as the sensor lug.
1-630-784-1000 Fax: 630-784-1651 Page 1 of 4 P/N 1011095 06/10
1-800-253-2991
5”
(127 mm)
4.7”
(119 mm)
5.87”
(149 mm)
NOTE: Dimensions are for reference only.
T1 T3 T2
T11 T5 T7T6 T8T4 T10T9
R6 DS2 DS1
K1
HI
K2
LO
Sensor Input
Red
White
Black
GND COMN.O. N.O.VAC N.C.COM
System Shutdown
Time-out Contacts
System Shutdown
Over-Temp. Contacts
Input Power
(24 VAC)
Page view 0
1 2 3 4

Summary of Contents

Page 1 - TFH Installation Information

A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188DimensionsPanel CutoutIMPORTANTPlease read these instruct

Page 2

A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188TFH Installation Information1-630-784-1000 Fax: 630-784-

Page 3 - 1-800-253-2991

A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 601881-630-784-1000 Fax: 630-784-1651 Page 3 of 4 P/N 10110

Page 4

A.J. Antunes & Co. Headquarters/Manufacturing180 Kehoe BoulevardCarol Stream, Illinois 60188 USAPhone (630) 784-1000Toll Free (800) 253-2991Fax: (

Comments to this Manuals

No comments