P/N 1010984 Rev. D 03/12
PLUMBING
NOTE: Miracle Steamer models are
designed to use cold tap water. Distilled
water may be used to reduce calcium/
mineral deposit buildup and reduce main-
tenance costs.
MS-150 MODELS
The MS-150 models have a self-contained
water tank. To fill the self-contained water
tank:
1. Open the Tank Cover on top of the
unit (Figure 3).
NOTE: Make sure filter inside tank is
installed properly.
2. Pour in cold tap water. The tank will
hold approximately 3 quarts (2.81
liters).
3. Close the Tank Cover.
NOTE: Do NOT overfill the unit’s water
tank. Only fill the tank to 90% full.
MS-250 MODELS
The MS-250 models require a direct cold
water hookup. A Water Inlet Hose and Strainer
Assembly (Figure 4) is supplied.
NOTE: Incoming water is controlled by a
normally closed (NC) solenoid valve locat-
ed inside the Steamer’s electrical housing.
1. Turn off the water valve (not supplied)
that provides water to the unit (Figure
4).
2. Connect the 1/4” (6.5 mm) I.D.
Flexible Tubing to the outlet side of
the Water Pressure Regulator and
secure using the Worm Clamp (Figure 4).
READY
Figure 3. Filling Water Tank
Filter
Tank Cover
Tank
NOTE: A Water Pressure Regulator must
first be installed (Figure 4). Failure to do
so will result in poor steaming and pos-
sible flooding. For a single steamer, use
Water Pressure Regulator P/N 7000314.
For two adjacent steamers, use Water
Pressure Regulator P/N 7000235.
3. Turn the water valve on.
4. Hold the Quick Disconnect Insert over
a bucket, then press and hold the
white plastic tip until there’s a good,
steady water flow. This will purge all
air out of the line.
5. Release the plastic tip and check
the pressure on the Water Pressure
Regulator. It should read 20 psi.
a.) If it reads less, increase the water
pressure by pulling the black knob up
and turning it clockwise.
b.) If it reads more, decrease the water
pressure by pulling the black knob up
and turning it counter clockwise.
NOTE: When adjusting the knob, you must
relieve the existing pressure by press-
ing the white plastic tip on the Quick
Disconnect Insert for 3 seconds. The Water
Pressure Regulator will then show the
new pressure.
6. Once the regulator reads 20 psi, push
the black knob down to lock it in
place.
7. Push the Quick Disconnect Insert into
the fitting at the rear of the unit until
it clicks (Figure 4).
Figure 4. Connecting Water Supply (MS-250 Only)
Connect Quick
Disconnect
Insert Here
Inlet Hose & Strainer
Assy. (Supplied)
Optional Water Pressure Regulator
with Strainer (P/N 7000314)
Shut Off Valve
(Not Supplied)
Cold
Water
Flow
Flexible Nylon Braided
1/4 " I.D. Tubing (Not Supplied)
Quick
Disconnect
Insert
Worm
Clamp
NOTE: The use of only one strainer is
acceptable instead of two.
CAUTION
Water pressure must not exceed 30 psi (2.1
kg/cm
2
or 207 kPa). Higher water pressures
may cause poor performance or flooding.
To reduce water pressure, install a water
pressure regulator, and set water pressure to
20–25 psi (1.4–1.7 kg/cm
2
or 138–172 kPa).